How to distinguish between ordinary motor and variable frequency motor?

 

Variable frequency motor insulation level requirements are higher
Generally, the insulation grade of the variable frequency motor is F grade or higher, and the insulation strength of the ground insulation and the turns is strengthened, and the ability of the insulation to withstand the impact voltage is particularly considered.

 

Variable frequency motor requires higher vibration and noise
The variable frequency motor should fully consider the rigidity of the motor components and the whole, and try to improve the natural frequency to avoid resonance with each force wave.

 

3. Variable frequency motor cooling method is different

The variable frequency motor generally adopts forced air cooling, that is, the main motor cooling fan is driven by an independent motor.

 

Different protective measures
Bearing insulation measures shall be adopted for variable frequency motors with a capacity exceeding 160 kW. Mainly due to the asymmetry of the magnetic circuit, it also produces shaft current.

When the currents generated by other high-frequency components work together, the shaft current will increase greatly, resulting in bearing damage, so insulation measures are generally taken.

For constant power variable frequency motors, when the speed exceeds 3000/min, special high temperature resistant grease should be used to compensate for the temperature rise of the bearing.

 

Different cooling system
The inverter motor cooling fan is powered by an independent power supply to ensure continuous heat dissipation.